SMI Inc.
SCIENTIFIC MATERIAL INTERNATIONAL
12219 SW 131 Avenue Miami, Florida 33186-6401 USA
Phone (305)971-7047 Facsimile (305) 971-7048
Attn: Larry Holt Date: 11-Apr-1995
Holt International LLC
1060 Yaple Rd. SMI/REF: 9508002-R
Kingston, OH 45644 Reissued for name change only.
Product: E-Z Grip Friction Drops
Dilution: As received Page 1 of 2
TOTAL IMMERSION CORROSION
per ASTM F 483
|
Alloy |
Wgt Loss (mg per 1x2 inch panel) |
WGT LOSS mg/cm2/24hrs |
|
|
AFTER 24HRS |
AFTER 168HRS |
||
|
AMS 4041 Clad Aluminum |
0.1 mg |
0.2 mg |
< 0.01 |
|
AMS 4049 Clad Aluminum |
0.1 mg |
0.2 mg |
< 0.01 |
|
AMS 4376 Magnesium dichromate treated per MIL-M-3171 Type III |
+ 1.1 mg |
+ 1.1 mg |
+ 0.04 |
No visible corrosion or attack on any of the above alloys.
Respectfully submitted,
Patricia D. Otero, SMI Inc.